DMX TESTER– SAVE SEQUENCE (DMX Control– Store Sequence)
Four individual sequences with up to 10 steps each can be created, saved and retrieved in UNI-
CON. In the main menu, select DMX Control, confirm the selection, then select Store Sequence
and confirm again. Now select the sequence you want to edit and confirm the selection (Sequen-
ce 1– Sequence 4). The submenu for editing the corresponding sequence is now displayed.
List of submenu items with explanations (confirm after editing):
Channel Edit Channel 1– 512
level 000– 255
Select channels and set corresponding values from 000 to
255 in the selected step
Fade Time: 0.0s– 30.0s Set the fade time of the selected step from 0.0 seconds to
30.0 seconds
Hold Time: 0.0s– 30.0s Set the duration of the selected step from 0.0 seconds to
30.0 seconds
Current Step: 1 - 10 Selection of the step to be processed (number of steps
depending on the maximum number of steps under Point
Max Steps)
Max Steps: 1 - 10 Set the maximum number of steps from 1 to 10
Clean Step NO Cancel selected step
YES Reset selected step
Clean
Sequence
NO Cancel selected sequence
YES Reset selected sequence
DMX TESTER– EXECUTE SEQUENCE (DMX Control– Execute Sequence)
In the main menu, select DMX Control, confirm the selection, then select Execute Sequence
and confirm again. Now select the sequence to be executed and confirm the selection (Sequence
1– Sequence 4).