Je bekijkt pagina 5 van 8
5
Hot module On/OFF Switch
RED LIGHT
Light turns red to
indicate power is
present.
AMBER LIGHT
Turns on when the
heater is cycling. When
cabinet reaches target
temperature the light
will turn off.
Start 1 hr. 2 hrs. 3 hrs. 4 hrs.
Temperature
190˚F (87,8˚C) 186˚F (85,6˚C) 184˚F (84,5˚C) 181˚F (82,8˚C) 179˚F (81,7˚C)
Hot
Hot Holding Test Results Temperature loss averaging 3˚F/hr (1,5˚C/hr)
Start 1 hr. 2 hrs. 3 hrs. 4 hrs.
Temperature
33.4˚F (0,8˚C) 34.2˚F (1,2˚C) 34.9˚F (1,6˚C) 36.1˚F (2,3˚C) 36.2˚F (2,3˚C)
Cold
Cold Holding Test Results Temperature gain averaging 0.7˚F/hr (0,C/hr)
Hot / Cold Holding Test Results for Passive Holding
V. Operating Instructions for Electric Use (continued)
For best operating results, the Pro Cart
Ultra
Passive holding carts should ideally be pre-heated or pre-chilled for at least
20 to 30 minutes before loading with food.
For holding hot food:
Pre-heat each empty cabinet by sliding a full-sized food pan lled with hot water onto the bottom rails. Close the cabinet door.
OR Simply place one or two Camwarmers
®
(1210PW - heated in the oven at 350˚F for 45 minutes) on a sheet pan and place onto
the bottom rails and close the cabinet door. Camwarmers
®
can remain in the cart to extend the holding time of hot foods beyond 4 hours.
For holding cold food:
Pre-chill each empty cabinet by sliding a full-sized food pan lled with ice water onto the top rails. Close the cabinet door.
OR Simply slide one or two Camchillers
®
(CP1220 - frozen at for 8 hours) to the top of the compartment and close the cabinet door.
Camchillers
®
can remain in the cart to extend the holding time of cold foods beyond 4 hours.
VI. Operating Instructions for Non-Electric Use
SET POINT SETUP
Press the Set key once and Set will be displayed.
Press the Set key again and set point value will be shown, blinking.
Use the Up and Down arrows to adjust the set point.
(Minimum 32.5˚F / ,28˚C, Maximum 40˚F / 4,4˚C)
Press the Set key to save the new set point.
Press Set and Down arrow keys at the same time to exit.
LED INDICATORS:
((•)) Indicates an Error or Alarm.
DISPLAY MESSAGES
In normal operation the probe temperature will be displayed. The display blinks
when waiting for a parameter to be saved or when there is an error saving a
parameter to memory. The following messages can also appear:
ERP1 Probe Error (check wiring or replace probe)
Eri Internal Parameter Error (factory default programming)
ALH High Temperature Alarm
ALL Low Temperature Alarm
ooo Open Probe Error
--- Short Circuited Probe Error
Cold module Controller
Set Key
Value Increase
Value Decrease
Cold module is factory set at 32.5˚F (.28˚C)
and can be adjusted up to 40˚F (4.4˚C)

Bekijk gratis de handleiding van Cambro PCUPH615, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.