L2 Features 120
Ingress Metering with ACL + Enable Metering(QoS)
1. Type the config terminal command into the terminal. Press the Enterkey.
2. Type the ip access-list extended 1002 command into the terminal to create an IP access-list. Press
the Enterkey.
3. Type the permit udp any any range 60000 65535 command into the terminal to specify the UDP
port rangeof the packets to beallowed. Press the Enterkey.
4. Type the exit command into the terminal to go back to the configuration mode. Press the
Enterkey.
5. Type the interface gi 0/1 command into the terminal to select the interface to be configured. Press
the Enterkey.
6. Type the ip access-group 1002 in command into the terminal to enable IP ACL on the interface.
Press the Enterkey.
7. Type the exit command into the terminal to go back to the configuration mode. Press the
Enterkey.
8. Type the meter 1 command into the terminal to create a meter and to go to the configuration-
meter mode. Press the Enterkey.
9. Type the meter-type srTCM cir 100000 cbs 4096 ebs 0 command into the terminal to set the
meter type as single rate three color marker metering and the committed information size as
100000, the committed burst size as 4096 and the excess burst size as 0. Press the Enterkey.
Bekijk gratis de handleiding van Cambium Networks cnMatrix EX2010-P, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Cambium Networks |
| Model | cnMatrix EX2010-P |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 32421 MB |
Caratteristiche Prodotto
| Kleur van het product | Grijs |
| Gewicht | 1600 g |
| Breedte | 250 mm |
| Diepte | 210 mm |
| Hoogte | 44 mm |