Installation 
Instructions
    If you have questions, call GE Appliances at 833-4BODEWELL (833-426-3393) 
or visit our website at: GEAppliances.com. In Canada, visit GEAppliances.ca or call 800.561.3344.
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and 
carefully.
Ŷ
  IMPORTANT — Save these 
instructions for local inspector’s use.
Ŷ
 IMPORTANT — Observe all governing 
codes and ordinances.
Ŷ
  Note to Installer – Be sure to leave these 
instructions with the Consumer.
Ŷ
  Note to Consumer – Keep these instructions for 
future reference.
Ŷ
  Skill level – Installation of this vent hood requires 
basic mechanical and electrical skills.
Ŷ
  Completion time – Approximately 1 to 3 hours
Ŷ
  Proper installation is the responsibility of the 
installer. 
Ŷ
  Product failure due to improper installation is not 
covered under the Warranty.
FOR YOUR SAFETY
WARNING
 Before beginning the installation, 
switch power off at service panel and lock the 
service disconnecting means to prevent power from 
being switched on accidentally. When the service 
disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, to 
the service panel.
CAUTION
 Due to the weight and size of these 
vent hoods and to reduce the risk of personal injury 
or damage to the product, TWO PEOPLE ARE 
REQUIRED FOR PROPER INSTALLATION.
WARNING
Disconnect all electrical power at 
the main circuit breaker or fuse box before installing.
WARNING
 TO REDUCE THE RISK OF FIRE, 
ELECTRIC SHOCK OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:
A.  Installation work and electrical wiring must be 
done by qualified person(s) in accordance with 
all applicable codes and standards, including 
fire-rated construction.
B.  Sufficient air is needed for proper combustion 
and exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent 
back drafting. Follow the heating equipment 
manufacturer’s guidelines and safety standards 
such as those published by the National Fire 
Protection Association (NFPA), the American 
Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE) and the local 
code authorities.
C.  When cutting or drilling into wall or ceiling, do 
not damage electrical wiring and other hidden 
utilities.
D.  Ducted fans must always be vented to the 
outdoors.
E.  Turn off breaker to adjacent rooms while working.
WARNING
 TO REDUCE THE RISK OF FIRE, 
USE ONLY METAL DUCT WORK.
Custom Insert Hood
UVC9420, UVC9480