Café UVC9420SLSS handleiding

80 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 80
10 49-2000930 Rev. 3
INSTALLATION CLEARANCES
This vent hood must be installed between the 30"
required minimum and 36" recommended maximum
above the cooking surface.
Ŷ$OZD\VUHIHUWRWKHFRRNWRSRUUDQJHLQVWDOODWLRQ
instructions for product-specific clearances.
NOTE: Installation height should be measured from
the cooking surface to the bottom edge of the cabinet
surface.
NOTE: UL requires any combustible surface to be a
minimum of 30" above the cooking surface. Lower
combustible surfaces may be covered to meet
requirements.
Ŷ7KHFXVWRPFDELQHWLQWHUQDOKHLJKWPXVWEH
minimum for vertical venting.
Ŷ7KLVKRRGPXVWEHYHQWHGWRWKHRXWGRRUV
Ŷ7KLVKRRGPD\EHPRXQWHGLQDZDOOFDELQHWRU
installed over an island.
NOTE: The exhaust duct on the hood is closer to
the rear of the hood. It is important to plan for the
alignment to the connection point of the hood.
*30" Minimum required
*36" Maximum recommended
Typically 36"
17" min.
12-1/2"
7-5/8"
Installation Preparation
INSTALLATION PREPARATION