Handleiding
Je bekijkt pagina 27 van 40

27
EN
NHM ≤ 250 μS/cm
TH < 8 °dH, Cl- ≤ 25 ppm (5 drops of
reagent*)
No water treatment
TH ≥ 8 °dH, Cl- ≤ 25 ppm (5 drops of
reagent*)
UNOX.Finest
Cl- > 25 ppm (5 drops of reagent*)
Reverse Osmosi System
NHM = 250 - 350 μS/cm
Cl- ≤ 20 ppm (4 drops of reagent*) UNOX.Finest
Cl- > 20 ppm (4 drops of reagent*)
Reverse Osmosi System
NHM = 350 – 450 μS/cm
Cl- ≤ 15 ppm (3 drops of reagent*) UNOX.Finest
Cl- > 15 ppm (3 drops of reagent*)
Reverse Osmosi System
NHM = 450 – 500 μS/cm
Cl- ≤ 10 ppm (2 drops of reagent*) UNOX.Finest
Cl- > 10 ppm (2 drops of reagent*)
Reverse Osmosi System
NHM ≥ 500 μS/cm
Reverse Osmosi System
* use the reagent in the UNOX
KSTR1081A kit
** hardness measured using the UNOX
KSTR1082A kit
WATER SPECIFICATIONS FOR THE STEAM CIRCUIT (STEAM INSIDE THE
OVEN CAVITY)
Free chlorine ≤ 0.1 ppm, Chloramines ≤ 0.1 ppm (mg/L)
TDS ≤ 125 ppm, Silica ≤ 12 ppm, pH 7 to 8.5, Total hardness (TH) ≤ 8 °d
Chlorides ≤ 25 ppm, Alkalinity ≤ 150 ppm as CaCO
3
The maximum chloride content, Cl-, is not a fixed value; it depends on the
calculated Non Hardness Measurement (NHM)
NHM = EC - (TH** x 30)
EC = electrical conductivity [μS/cm]
TH = total hardness** [° dH - German degrees]