TROUBLESHOOTING
Problem Cause Corrective Action
No water comes out of the
water lter system.
Filter(s) are plugged. Replace lter(s).
Vapor-lock. Rinse system.
Low ow from the water lter
system.
Partially plugged lter(s). Replace lter(s).
Barrel valve partially closed. Rotate lter to fully open position.
Water has carbon nes. All carbon lters have carbon nes
on startup.
Rinse system.
Filter leaks from lter interface. O-Ring is out of position in gland. Inspect O-Ring and set in gland.
Nicked or cut O-Ring(s) on lter. Replace O-Ring or lter.
Missing O-Ring(s) Install O-Ring(s).
Water comes out of the upper
Filter Integrity Port (WQ only).
O-Ring is out of position in gland. Inspect O-Ring and set in gland.
Nicked or cut O-Ring(s) on lter. Replace O-Ring or lter.
Missing O-Ring(s). Install O-Ring(s).
Water comes out of the lower
Filter Integrity Port (WQ only).
Cracked carbon block. Replace lter(s).
Water tastes bad. Cracked carbon block (bypass). Replace lter(s).
Nicked or cut O-Ring(s) on lter. Inspect O-Ring and set in gland.
Pre-lter/scale cartridges are in
parallel.
Change pre/post cartridges to
series.
Biological growth in plumbing. Sanitize plumbing and/or system.
Water leaks from ttings. O-Ring is out of position in gland. Inspect O-Ring and set in gland.
Nicked or cut O-Ring(s) on tting. Replace O-Ring or lter.
Missing O-Ring(s). Install O-Ring(s).
Water leaks from back of mani-
fold/wall.
O-Ring is out of position in gland. Inspect O-Ring and set in gland.
Nicked or cut O-Ring(s) on tting. Replace O-Ring or lter.
Missing O-Ring(s). Install O-Ring(s).
Water leaks from barrel valve. Improper the assembly of barrel
valve sub-assembly.
Replace the barrel valve sub-
assembly.
Pressure gauge indicates 0 psi. Water is turned off. Turn water on.
Pressure gauge has failed. Replace pressure gauge.
Rinse valve is leaking. Open/close lever not closed. Close open/close lever all the way.
Rinse valve failure. Replace rinse valve.
56000.0500 B
7/21 © 2021 Bunn-O-Matic Corporation
Page 15
www.bunn.com
803426