Bunn FMD-2 handleiding
Handleiding
Je bekijkt pagina 5 van 9

5
INITIAL SET-UP
1. Locate the drip tray assembly beneath the dispenser nested in the packing material.
2. Remove the drip tray and the drip tray cover and set them aside.
3. Remove the water strainer assembly from the drip tray and set it aside.
4. Remove the four legs from the packaging material, apply non-skid pads to the bottom of the legs and se-
curely install the legs in the dispenser base.
29112 092415
ELECTRICAL REQUIREMENTS
CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.
The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded service rated 120
volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.
The 120/208 and the 120/240 versions of this dispenser has an attched cordset. The mating connector must be
a NEMA 14-20R.
The 220-240 volt version of this dispenser has an attached cordset.
Refer to the dispenser’s dataplate and local/national electrical codes for exact voltage requirement.
ELECTRICAL HOOK-UP
CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Open the front door of the dispenser and place the heater switch in the “OFF” (upper position).
4. Connect the dispenser to the power source.
5. If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If plumb-
ing has been hooked-up, the dispenser is ready for Initial Fill & Heat.
Bekijk gratis de handleiding van Bunn FMD-2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Bunn |
| Model | FMD-2 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 1167 MB |