Home > Routine Maintenance > Replace Supplies > Reset the Drum Counter
Reset the Drum Counter
When you replace the drum unit with a new one, you must reset the drum counter by completing the following
steps:
IMPORTANT
DO NOT reset the drum counter unless you are replacing the drum unit.
>> HL-L2402D
>> HL-L2400DW/HL-L2400DWE/HL-L2442DW/HL-L2445DW/HL-L2447DW/HL-L2460DN/HL-L2865DW
HL-L2402D
1. Make sure the machine is turned on.
2. Open the front cover.
3. Press and hold Go for about four seconds until all LEDs light up. When all four LEDs are lit, release Go.
4. Close the front cover of the machine.
5. Make sure the Drum LED is now off.
HL-L2400DW/HL-L2400DWE/HL-L2442DW/HL-L2445DW/HL-L2447DW/HL-L2460DN/
HL-L2865DW
1. Make sure the machine is turned on.
2. Make sure the machine's cover is closed.
3. Press OK and a at the same time.
4. Press OK to select [Drum].
5. Select [Reset] to reset the drum counter.
Related Information
• Replace Supplies
Related Topics:
• Error and Maintenance LED Indications
• Error and Maintenance Messages
• Replace the Drum Unit
198
Bekijk gratis de handleiding van Brother HL-L2442DW, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Brother |
| Model | HL-L2442DW |
| Categorie | Printer |
| Taal | Nederlands |
| Grootte | 20718 MB |
Caratteristiche Prodotto
| Kleur van het product | Grijs |
| Ingebouwd display | Ja |
| Gewicht | 6000 g |
| Breedte | 356 mm |
| Diepte | 360 mm |