Broan ZB110M handleiding

44 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 5 van 44
ZB80M
n
ZB110M Installation Guide
Page 5
3
4
1
2
New Construction Installation
5
Connect Wires and Install Knockout Plate
Run 120VAC electrical wiring to the installation location.
Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
Connect wires as shown in wiring diagram.
Screw from
Parts Bag
Attach cable clamp to Knockout
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Connect wires
FAN
SENSOR/
CONTROL
BLK
WHT
BLK
ORG
BRN
MASTER MANUAL-ON
GRD
WHT
BLK
GRD
WHT
BLK
BLU
120 VAC
LINE IN
STANDARD OR MULTI-
FUNCTION WALL SWITCHES
RED
14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
SENSOR/
CONTROL
RED
MASTER
ON/OFF
SWITCH*
MANUAL
ON
SWITCH*
KNOCKOUT
PLATE
RECEPTACLES
120 VAC
LINE IN
SWITCH BOX
BLACK
WHITE
RED
BLUE
*
purchase separately
SENSOR
CONTROL
SWITCH*
GROUND
(green or bare)
ORANGE
BROWN
See OPERATION section on page 12
for details.
MASTER switch turns fan system
on and shuts it off for fan cleaning and
maintenance purposes.
SENSOR/CONTROL switch turns
motion control automatic operation on/off.
MANUAL-ON switch directly increases
fan operation to certified airflow rate.
MASTER and SENSOR/CONTROL
switches can be combined (see page 10).
MASTER switch along with or separate
from SENSOR/CONTROL switch may be
located where it is not easily accessed
for everyday usage; they may need to
be labeled and located where it can’t be
turned on without being seen from fan to
comply with local and national codes.