Broan QTXE110150DCL handleiding

12 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 2 van 12
2
INSTALLATION STEPS
1
1
Some models only:
Select 110, 130 or 150
CFM based on your
room size and
desired
air ow.
Housing
mounted to
I-joists.
Use I-joist
spacer block
(provided).
Housing
mounted
anywhere
between
I-joists
using
hanger bars.
Housing
mounted to
joists.
Housing
mounted
anywhere
between
joists
using
hanger bars.
Housing
mounted to
truss.
Housing mounted
anywhere between
trusses using
hanger bars.
TYPICAL INSTALLATIONS
110 130 150
1
2
Plug-in and
secure blower
to housing.
1
2
Screws from
parts bag
1
3a
Mount housing to joist.
SPACER
(use for
mounting
to I-Joist)
I-JOIST
Hold housing in place so
that bottom edge of housing
will be flush with finished
surface of ceiling. For
1/2” thick ceiling material,
position bottom of each
mounting flange flush with
the bottom of joist. The
housing mounts with four
(4) screws or nails. Screw or nail housing to joist through lowest
holes in each mounting flange, then through highest holes.
NOTE: Mounting to I-JOIST (shown) requires use of SPACERS
(included) between the highest hole of each mounting flange and
the I-joist.
OR

Bekijk gratis de handleiding van Broan QTXE110150DCL, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBroan
ModelQTXE110150DCL
CategorieVentilator
TaalNederlands
Grootte3342 MB