Broan HRVH100S handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 20 van 40
20
9. TROUBLESHOOTING (CONTD)
PROBLEMS POSSIBLE CAUSES YOU SOULD TRY THIS
6
The wall control does not
work.
The wires may be in reverse
position.
The wires may be broken.
The wire in the wall OR the wall
control may be defective.
Ensure that the color coded wires have been connected to their
appropriate places.
Inspect every wire and replace any that are damaged.
Remove the wall control and test it right beside the unit using
another shorter wire. If the wall control works there, change the
wire. If it does not, change the wall control.
7
The VB60W push button
timer does not work OR
its indicator light does not
stay on.
The wires may be in reverse
postion.
The VB60W button may be
defective.
8
The motor does not work. The fuse may be defective.
The motor may be defective.
The motor or capacitor
may be defective.
Unplug the product from the outlet. Check if fuse F1 is blown.
In that case, discontinue using the unit and contact technical
support.
NOTE: Refer to Section 6 Wiring diagram.
If the voltage reading is 120 VAC on J4, change the defective
motor.
Using a multimeter, check the ohms value on motor connector.
For BLUE and BLACK motor wires, the right value is ± 43 ohms.
For BLUE and BROWN motor wires, the right value is ± 48
ohms. For BROWN and BLACK motor wires, the right value is
± 91 ohms. If the ohms values are the same, the motor is not
defective. Replace the motor capacitor.
9
The defrost cycle does
not work (the fresh air
duct is frozen) OR the
fresh air distributed is very
cold.
Ice deposits may be hindering
the damper operation.
The damper rod or the port
damper itself may be broken.
The damper actuator or circuit
board may be defective.
Remove the ice.
Inspect these parts and replace if necessary.
See point 5.
10
The integrated defrost
control push button does
not work.
The 30-second boot sequence
is not completed.
See Section 4.1 Booting Sequence.
Ensure that the color coded wires have been connected to their
appropriate places.
• Jump the OL and OC terminals.
If the unit switch to high speed,
remove the VB60W push button
and test it right beside the unit
using another shorter wire. If it works here, change the wire. If it
doesn’t, change the VB60W push button.
NO C NC I OC OL Y R G B
VE0098
If the problem is still not solved, call our Technical Support: 1-800-558-1711.

Bekijk gratis de handleiding van Broan HRVH100S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBroan
ModelHRVH100S
CategorieAirco
TaalNederlands
Grootte5869 MB