Install Ductwork (Ducted Installations Only)
NOTE: Distances over 30” are at the installer and user discretion.
1. Determine whether hood will discharge vertically (3¼” x10” or 7” round), or
horizontally (3¼” x10” only).
2. Decide where the ductwork will run between the hood and the outdoors.
3. The ducting from this fan to the outside of the building has a strong effect on the
air flow, noise and energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve their rated airflow.
Refer to the table below to help you plan the most efficient installation.
4. Install wall cap or roof cap (sold separately); ensure there is no leak in house
insulation.
5. Connect metal ductwork to cap and work back towards the hood location. Use 2”
metal foil duct tape to seal the joints between ductwork sections.
3¼” X10”
HORIZONTAL
MAXIMUM
DUCT LENGTH
3¼” X10
VERTICAL
MAXIMUM
DUCT LENGTH
7" ROUND
MAXIMUM
DUCT LENGTH
ROOF OR
WALL CAP
WITH DAMPER
ELDOW(S)*
(90° AND/OR
45°)
90 ft. 94 ft. 78 ft. 1 0
82 ft. 86 ft. 65 ft. 1 1
74 ft. 79 ft. 51 ft. 1 2
* Standard elbows with 1” internal radius
NOTE: 6" round ducting is possible but may reduce exhaust efficiency.