Handleiding
Je bekijkt pagina 109 van 297

Description of the oven
10
Installation
Installation
Description of the oven
Tips
Do not use your appliance immediately
(wait approximately 1 to 2 hours) after moving
it from a cold location to a hot location, as the
condensation may cause a malfunction.
Neutral
(N)
Phase
(L)
bleu
green yellow
Black,brown or
red
Warning
The safety wire (green-yellow) is connected
to the appliance’s terminal and must be
connected to the earth terminal of the elec-
trical set-up.
The fuse in your set-up must be 16 amperes.
ELECTRICAL CONNECTION
Your oven must be connected with a (standard)
power cable with 3 conductors of 1.5mm
2
(1 live
+ 1 neutral + earth) which must be connected to
a 220-240V
~
single-phase grid by means of a 1
live + 1 neutral + earth CEI 60083 standard power
socket or via an all-poles cut-off device in compli-
ance with the installation rules.
Terminal
We cannot be held responsible for any accident result-
ing from inexistent, defective or incorrect earthing.
Bekijk gratis de handleiding van Brandt BMS7120X, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Brandt |
| Model | BMS7120X |
| Categorie | Magnetron |
| Taal | Nederlands |
| Grootte | 28302 MB |
Caratteristiche Prodotto
| Apparaatplaatsing | Ingebouwd |
| Inhoud (binnenkant) | 26 l |
| Soort bediening | Touch |
| Magnetronvermogen | - W |
| Kleur van het product | Black, Stainless steel |






