Description of the oven
10
Installation
Installation
Description of the oven
Tips
Do not use your appliance immediately
(wait approximately 1 to 2 hours) after moving
it from a cold location to a hot location, as the
condensation may cause a malfunction.
Neutral
(N)
Phase
(L)
bleu
green yellow
Black,brown or
red
Warning
The safety wire (green-yellow) is connected
to the appliance’s terminal and must be
connected to the earth terminal of the elec-
trical set-up.
The fuse in your set-up must be 16 amperes.
ELECTRICAL CONNECTION
Your oven must be connected with a (standard)
power cable with 3 conductors of 1.5mm
2
(1 live
+ 1 neutral + earth) which must be connected to
a 220-240V
~
single-phase grid by means of a 1
live + 1 neutral + earth CEI 60083 standard power
socket or via an all-poles cut-off device in compli-
ance with the installation rules.
Terminal
We cannot be held responsible for any accident result-
ing from inexistent, defective or incorrect earthing.