Bosch GMC 600-15 Professional handleiding
Handleiding
Je bekijkt pagina 22 van 363

22 | English
(8) COM input terminal (earth connection (return con-
ductor) for measuring voltage, continuity and res-
istance)
(9)
Red test lead
(10)
Black test lead
(11)
Screw (2×) for attaching the battery compartment
cover
(12)
Battery compartment cover
(13)
Inlay in the battery compartment cover
(14)
Battery pack locking mechanism
(15)
Li-ion battery pack
A)
(16)
Locking mechanism of the Li-ion battery pack
A)
(17)
Magnetic hanger
A)
(18)
Protective bag
(19)
Protective caps
A)
This accessory is not part of the standard scope of deliv-
ery.
Display Elements
(a)
Measured value "frozen"
(b)
Continuity test
(c)
Sound off
(d)
Battery warning
(e)
Measured value
(f)
Unit of measurement
(g)
Direct current/alternating current display
(h)
Sign of measured value (polarity)
(i)
Warning if voltage > 30 V
Technical data
Clamp Meter GMC 600-15
Article number
3 601 K77 6..
Measuring range for voltage 600VAC/DC
Measuring range for current 600AAC
Measuring range for resistance 40MΩ
Continuity testing ●
True RMS (root mean square
measurement)
●
General
Operating temperature –10°Cto+50°C
Storage temperature
A)
−40°Cto +70°C
Relative air humidity max. 90%
Max. altitude 2000m
Pollution degree according to
IEC61010-1
B)
2
Automatic switch-off after ap-
prox.
20min
Weight
C)
347g
Protection rating IP54
Safety class CAT III 600V
D)
CAT IV 300V
E)
Dimensions 49.6×229.2×
83.0mm
1 609 92A A6W | (20.01.2025) Bosch Power Tools