Touch the filter status check/reset button .
Wash your hands after cleaning the filter.
[Figure 9
Removing and cleaning the filter]
4.4 Replacing the filter
CAUTION
Wear a mask and gloves when cleaning the filter surface and/or replacing
the filter.
The air purifier is equipped with a filter replacement indicator to
ensure that the air purification filter is in optimal condition when the air
purifier is operating.
NOTICE
The filter is not washable or reusable.
CAUTION
Always turn off the air purifier and unplug it from the electrical outlet
before replacing the filter.
Switch off the air purifier and unplug it from the power socket.
Lay the appliance horizontally in a steady surface.
Rotate and pull the bottom cover and remove it from the appliance.
Pull the filter from the appliance.
Remove the plastic cover of the new filter.
Insert the new filter into the appliance.
Push and rotate the bottom cover.
Place the appliance back into vertical position.
Insert the plug of the air purifier in the power socket.
Touch the power button to switch on the appliance.
Touch and hold the filter status check/reset button to reset the
filter lifetime counter.
Wash your hands after replacing the filter.
Note:
Do not smell the filter as it has collected pollutants from the air.
4.5 Resetting the filter
When the filter indicator button turns red replace the filter immediately.
The filter may be replaced before the filter button turns red. The filter
lifetime counter needs to be reset manually after its replacement:
Long press for 3 seconds the filter button to reset the filter
lifetime counter. The red back-light will switch-off.
5 Moving and storage
Moving
Use two hands to hold the appliance when moving it.
Storage
Turn off the air purifier and unplug it from the power socket.
Clean the air purifier, the particle sensor and the surface of the filter
( Chapter 4 "Cleaning and maintenance", Page 32).
Let all parts airdry before storing.
Wrap the filter in air-tight plastic covers.
Store the air purifier and the filter in a cool, dry location.
Wash your hands after handling the filter.
6Troubleshooting
This chapter summarizes the most common issues that may occur with
the appliance. If the solution is not found in the table below, please
contact an authorized service technician.
Table 4 Problems and solutions
Problem Possible solution
The airflow that comes out
of the air outlet is
significantly weaker than
before.
The surface of the filter is dirty. Clean the
surface of the filter ( Chapter 4
"Cleaning and maintenance").
The air quality does not
improve, even though the
appliance has been
operating for a long time.
Check if the plastic cover is removed
from the filter.
The filter has not been placed in the
appliance. Make sure that the filter is
properly installed.
The particle sensor is wet. The
humidity level in the room is high and
causes condensation. Make sure that
the particle sensor is clean and dry
( Chapter 4 "Cleaning and
maintenance").
Room size is large or the outdoor air
quality is poor. For optimum
purification performance, close the
doors and windows when operating
the air purifier.
There are indoor pollutants. For
example, smoking, cooking, incense,
perfume or alcohol.
Filter has reached the end of life.
Replace the filter with a new one.
The color of the air quality
light always stays the
same.
The particle sensor is dirty. Clean the
particle sensor ( Chapter 4 "Cleaning
and maintenance"). If the air quality is
good, the light should be blue at all times.
The appliance produces a
strange smell.
The first few times using the appliance, it
may produce a plastic smell. This is
normal. However, if the appliance
produces a burnt smell even after
removing the filter, contact support
services.The filter may produce smell
after being used for a while because of the
absorption of indoor gases. It is
recommended to reactivate the carbon
filter by putting it in direct sunlight. If the
smell persists, replace the filter.
The appliance is very loud. The appliance is operating at a high
speed, as set in manual mode.
In Auto mode, if the appliance is too
loud, it may be operating at high
speed, because poor air quality has
been detected. Switch to lower fan
speed.
If there is an unusual sound, contact
support services.
If anything drops into the air outlet, it
may also cause an unusual loud sound.
Immediately switch off the appliance,
turn the appliance upside down, to get
foreign objects out of the appliance.

Bekijk gratis de handleiding van Bosch Air 1000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBosch
ModelAir 1000
CategorieLuchtreiniger
TaalNederlands
Grootte18158 MB