9.2. Over-heating
When the thermal probe on the Power board detects a room temperature of >100°C, all the thermal elements of the oven automatically 
turn off. If this persists for more than 1 minute, the clock display shows “STOP”, and every command on the key board is ignored until 
the temperature goes below this limit.
9. MALFUNCTION SIGNALS
9.1. Detecting malfunctions
When a malfunction occurs, the control system begins to monitor this signal and considers it plausible only if it persists for more than 
1 minute. If during this minute another malfunction presents itself, the system considers it plausible if it persists for more than 4 se-
conds. 
When the malfunction is plausible,  the system passes to the Malfunction display mode: the oven is off, all the loads are deactivated, 
and the “Err” message appears, alternating with the type of malfunction detected: 
“Shor” : oven probe in short circuit
“OPEN”: oven probe in open circuit and not connected
“ntc1” : thermal probe on Power board
During this phase, the malfunction signal  can be “annulled” by pressing any key: if the malfunction is still present, everything returns 
to the display mode after 1 minute. 
If the malfunction is not autonomously resolved, the control continues to indicate “Err”, without any additional explanation. 
If a probe malfunction occurs, the system reacts as if a temperature higher than 500°C has been reached. 
Bekijk gratis de handleiding van Bompani BO243EA/E, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Bompani | 
| Model | BO243EA/E | 
| Categorie | Oven | 
| Taal | Nederlands | 
| Grootte | 10718 MB | 
Caratteristiche Prodotto
| Soort bediening | Sensor | 
| Kleur van het product | Roestvrijstaal | 
| Ingebouwd display | Ja | 
| Breedte | 596 mm | 
| Diepte | 524 mm | 