CAUTION
CAUTION
:
:
Make sure you keep the LC connectors on the ber cable and SFP modules covered when not in use. Leaving connectors uncovered could
Make sure you keep the LC connectors on the ber cable and SFP modules covered when not in use. Leaving connectors uncovered could
lead to damage and signal degradation.
lead to damage and signal degradation. 
SFP+ 12G Optical Modules LC Duplex Fiber Connector
         
IP Stream Out
The IP stream(s) can be enabled and congured from the Web Interface of the camera. The camera must be connected to a Local Area Network (LAN) using a CAT6
cable through either a switch or direct connection to a computer in order to access the web interface. Streaming from the camera requires internet (WAN)access.
The following steps should be followed:
1. Connect the camera to the network by inserting one end of a CAT6 cable into the 10/100/1000 LAN port of the camera and the other end either into a switch or
directly into a computer.
2. OpenanHTML5-enabled web browser on a computer and enter the IP address of the camera. By default, the camera is set to 192.168.0.13. The IP address can
also be located under the “Status” menu of the camera’s On-Screen Display (OSD) or by using Bolin Technology’s IPC Search Tool in the Download Center.
3. Select “AV Setup” from the menu on the left-side of the Web Interface. From here, enable and congure the IP streams as needed. For more details, refer to the
“Web Interface Conguration” section of this user guide.
Control Input
The R9 PTZ cameras havemultiple ways of being controlled thatcan be used simultaneouslyto provide the user with the exibility they need for their setup. The
control methods are as follows:
Infrared (IR) Remote Controller
The IR remote included with the device is capable of controlling up to 3 unique IR channels. IR channels can be set with the toggle switch on the back of the camera
or through the Web Interface.
The remote is designed to function optimally from short distances and requires a line-of-sight with the camera. The I/O panel of the camera incorporates an IR
receiver to accept commands from the remote. To use the IR Controller, the following steps are recommended:
1. Before powering on the camera, the desired IR channel should be selected using the IR Channel Selector located on the back of the camera. Channels 1-3 are
available for selection. If multiple cameras are in use, it is advisable to assign different IR channels to cameras that are in close proximity to each other to
prevent unintended changes.
2. Once the channel has been selected, the camera should be powered on.
3. On the IR remote, the “Camera IR ID” that corresponds with the selected channel on the camera should be chosen. The remote is now ready to be used to
congure or control the camera.
NOTE
NOTE
:
:
When you’re using the IR Remote, make sure to either power off any nearby cameras or set them to a different IR ID. If there are cameras within
When you’re using the IR Remote, make sure to either power off any nearby cameras or set them to a different IR ID. If there are cameras within
range that are set to the same IR ID, their settings might be altered.
range that are set to the same IR ID, their settings might be altered.
Functions of the IR Controller: