Blustream MX44KVM handleiding

21 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 16 van 21
MX44KVM USER MANUAL
www.blustream.com.au | www.blustream-us.com | www.blustream.co.uk16
RS-232 Configuration and Telnet Commands
COMMAND ACTION
? / HELP Print System Status And Port Status
STATUS Print All Input Status
INSTA Print All Output Status
OUTSTA Print All GPIO Input Status
GPOUTSTATUS Print All GPIO Output Status
GPINSTATUS Print All Preset Configurations
PRESETSTATUS Print All Cascade Status
CASCADESTATUS Set System Power On Or O
PON/OFF Set System Key Control On Or O
KEY ON/OFF Reset System To Default Setting
RESET
Set System Front Panel IR Control On Or O
(Type ‘Yes’ To Confirm, Or Send Other Command To
Discard)
USBOUT xx FR yy
Set USB HOST From DEVICE:yy
xx = [01-04] : USB HOST 1 - 4
yy = [01-04] : USB DEVICE 1 - 4
yy = 00 : All USB DEVICE
PRESET pp SAVE
Save Current Output Connections To Preset pp
Config
pp = [01-09] : Presets 1 - 9
PRESET pp CLR
Delete Preset pp Config
pp = [00-09] : 00 : All Presets, pp = [01-09]: Preset 1 - 9
PRESET pp APPLY
Apply Preset pp Config To Output Connection
pp = [01-09] : Presets 1 - 9
GPIOENABLE x
Set GPIO Enable/Disable
x = [0-1] 0 : Disable, 1 : Enable
AUTO-SWITCHING
ON/OFF
Set Auto-Switching Mode On/O
HOST xx FR yy
Sets Correspondence Between Input And Input
Cascades
xx = [01-04] : USB HOST 1 - 4
yy = [01-16] : AV INPUT 1 - 16
DEVICE xx OUT yy
Sets The Correspondence Of The Output Cascades
xx = [01-04] : USB DEVICE 1 - 4
yy = [01-16] : AV OUTPUT 1 - 16
OUTPIN xx MODE yy
TIME zzzz
Set GPIOOUTpin: xx Mode: yy Time: zzzz
xx = 00 : GPIO All
xx = [01-04] : GPIO 1 - 4
yy = 00 : Close Output Mode
yy = [01-03] : Mode 1 - 3 (1: output 5v 50mA, 2: output
12v 50mA, 3: Contact Closure)
zzzz = [0005-1800] : time 0.5s - 180s
INPIN xx MODE yy
SN z
Set GPIOINpin: xx Mode: yy Sign: z
xx = 00 : GPIO All
xx = [01-04] : GPIO 1 - 4
yy = [00-02] : Mode 0 - 2 (0-Turn O All Detection
Modes,1-Turn On Standby Mode Detection,2-Turn On
Auto-Switching Mode Detection)
z = [0-1] : SN 0 - 1 (Trigger Level: 0 - Low Level Valid,
1 - High Level Valid)
COMMAND ACTION
RS232BAUD z
Set RS232 Baud Rate To xx
z = 1 - 2400, 2 - 4800, 3 - 9600, 4 - 19200, 5 - 38400, 6 -
57600 (Default), 7 - 115200
RS232ONOUT z:a:b
Command a Whose Baud Rate Is z On Output RS232-
2
z = a ASCII, h HEX
a = 1 - 2400, 2 - 4800, 3 - 9600, 4 - 19200, 5 - 38400, 6 -
57600 (Default), 7 - 115200
b = RS231 Command
NET DHCP ON/OFF Set Auto IP(DHCP) On Or O
NET IP xxx.xxx.xxx.xxx Set IP Address
NET GW xxx.xxx.xxx.
xxx
Set Gateway Address
NET SM xxx.xxx.xxx.
xxx
Set Subnet Mask Address
NET RB Set Network Reboot And Apply New Config!!!
NET TN xxxx Set Telnet Port
NET TN ON/OFF Set Telnet Port On Or O
NET TN8000 ON/OFF Set Telnet Port 8000 On Or O

Bekijk gratis de handleiding van Blustream MX44KVM, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBlustream
ModelMX44KVM
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3929 MB

Caratteristiche Prodotto

Kleur van het productZwart
Breedte273 mm
Diepte168 mm
Hoogte25 mm
Gewicht verpakking2650 g