29
COMMAND ACTION
MV mm LAYOUT
USER <x1,y1,h1,v1>
<x2,y2,h2,v2>
<x3,y3,h3,v3>
<x4,y4,h4,v4> FR aa
bb cc dd
Set Output Layout To User Defined:<x,y,h,v> From
Input:aa/bb/cc/dd
mm=[01..02]: Select Multiview Index
x=[00...4095]: X Coordinate Of Window 1/2/3/4
Top-le Corner
y=[00...2159]: Y Coordinate Of Window 1/2/3/4
Top-le Corne
h=[00...4095]: The Horizontal Size Of Window
1/2/3/4
v=[00...2159]: The Vertical Size Of Window 1/2/3/4
aa=[01...04]: Select One Input Port For Window 1
Source
bb=[01...04]: Select One Input Port For Window 2
Source
cc=[01...04]: Select One Input Port For Window 3
Source
dd=[01...04]: Select One Input Port For Window 4
Source
Note: aa, bb, cc, dd are optional
MV mm AUDIO FR yy
Set Output Audio From Input yy
mm=[01...04]: Select One Output Port
yy=[01...04]: Select One Input Port
yy=[05]: Analogy Input
MV mm PRESET pp
NAME name
Set Multiview Name to name
mm=[01..02]: Select Multiview Index
pp=[01..8]: Select Preset Index name: Max 16 char
MV mm PRESET pp
LAYOUT xx FR aa bb
cc dd
Set Preset:pp To Layout Index:xx From Input:aa/bb/
cc/dd
mm=[01..02]: Select mv Index
pp=[01..08]: Select Preset Index
xx=[01..05]: Select Layout Index
aa=[01...04]: Select One Input Port For Window 1
Source
bb=[01...04]: Select One Input Port For Window 2
Source
cc=[01...04]: Select One Input Port For Window 3
Source
dd=[01...04]: Select One Input Port For Window 4
Source
MV mm PRESET
pp LAYOUT USER
<x1,y1,h1,v1>
<x2,y2,h2,v2>
<x3,y3,h3,v3>
<x4,y4,h4,v4> FR aa
bb cc dd
Set Preset:pp Layout To User Defined:<x,y,h,v> From
Input:aa/bb/cc/dd
mm=[01..02]: Select Multiview Index
x=[00...4095]: X Coordinate Of Window 1/2/3/4
Top-le Corner
y=[00...2159]: Y Coordinate Of Window 1/2/3/4
Top-le Corne
h=[00...4095]: The Horizontal Size Of Window
1/2/3/4
v=[00...2159]: The Vertical Size Of Window 1/2/3/4
aa=[01...04]: Select One Input Port For Window 1
Source
bb=[01...04]: Select One Input Port For Window 2
Source
cc=[01...04]: Select One Input Port For Window 3
Source
dd=[01...04]: Select One Input Port For Window 4
Source
MV mm PRESET
STATUS
Print Preset Config Status
COMMAND ACTION
MV mm PRESET pp
SAVE
Save Current Config To Preset:pp
pp=[01..08]: Select Preset Index
MV mm PRESET pp
APPLY
Apply Preset:pp Config
pp=[01..08]: Select Preset Index
NET STATUS Show NET Settings
NET DHCP ON/OFF Set Auto IP(DHCP) On Or O
NET IP xxx.xxx.xxx.xxx Set IP Address
NET GW xxx.xxx.xxx.
xxx
Set Gateway Address
NET SM xxx.xxx.xxx.
xxx
Set Subnet Mask Address
NET TCPPORT xxxx Set TCP/IP Port
NET TCPPORT ON/OFF Set TCP/IP On Or O
NET TN xxxx Set Telnet Port
NET TN ON/OFF Set Telnet On Or O
NET WEB ON/OFF Set Web Access On Or O
NET HTTPS ON/OFF Set Https Access On Or O
NET RB Set Network Reboot And Apply New Config!!!
NET DNS xxxx Set DNS Domain Name To xxxx
RS-232 Configuration and Telnet Commands (continued)