The default maximum grid input current is 12A.
9. Adjust Grid Input Current
Note: If the current is set above 10A, the Premium 200 V2 switches to Turbo
charging mode. For settings of 10A or below, it switches to Standard charging mode.
When the battery runs out and the unit shuts down, it saves the ON/OFF status of the
AC and DC power buttons.
If connected to grid power, the saved settings will automatically restore when the
battery reaches 5%.
If not connected to grid power, the settings will only restore if the battery reaches 5%
and at least 30 minutes have passed since the unit turned off.
For example, in standard UPS mode, if a refrigerator is plugged into the AC outlet of the
Premium 200 V2 and the grid power goes out, the unit will provide immediate backup
power. If the battery depletes, the unit will shut off but retain the AC output status as ON.
When grid power returns and the battery is above 5%, the unit will automatically turn
the AC output back ON to continue powering the refrigerator.
10. System Switch Recovery
Note:
During recovery, the AC and DC output settings can be adjusted via the app.
To restore power immediately, turn off this feature.
EN
JUST POWER ON
20