14. Troubleshooting & FAQs
Error Code Description
Inverter overload
Inverter short circuit
PV overvoltage
PV overtemperature
Charging temperature too high
Charging temperature too low
Discharging temperature too high
Discharging temperature too low
Grid overfrequency
Grid underfrequency
/
E001
E002
E003
E033
E039
E085
E086
E087
E088
E115
E116
Others
Solutions
• Check device power usage.
• Reduce load if too high.
• Place the unit in an ambient temperature
range of 0°C to 40°C (32°F to 104°F).
• Wait 10 mins for the unit to cool down.
• Turn on the AC output again.
• Check devices for short circuits.
• Disconnect and fix.
• Make sure the PV input voltage is within 12V-60V.
• Wait 10 mins for the unit to cool down.
• Re-enable the PV input.
• Wait for the unit to cool down before using it
again.
• Wait for the unit to cool down before using
it again.
• Place the unit in an ambient temperature
range of -20°C to 40°C (-4°F to 104°F).
• Verify home grid frequency.
• Contact utility company if necessary.
• Verify home grid frequency.
• Contact utility company if necessary.
• Contact BLUETTI support for assistance.
Inverter overtemperature
protection, AC output off
Battery Expansion Port
Parallel Port
Interface P050A
51.2VDC, 90A Max.
JUST POWER ON 27
EN
Bekijk gratis de handleiding van Bluetti Apex 300, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Bluetti |
Model | Apex 300 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 4501 MB |