Blodgett DFG-100 handleiding

26 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 26
11
Installation
Gas Connection
PRESSURE REGULATION AND TESTING
DFG-100-3 ovens are rated at 55,000 BTU/Hr. (16.2
kW) (58 MJ) per section. DFG-200-L ovens are rated at
60,000 BTU/Hr. (17.6 kW) (63 MJ) per section. Each oven
has been adjusted at the factory to operate with the type
of gas specied on the rating plate.
INLET PRESSURE
Natural Propane
Min Max Min Max
W.C. 7.0 10.5 11.0 13.0
kPa 1.742 2.61 2.74 3.23
MANIFOLD PRESSURE
Natural Propane
W.C. 3.5 10.0
kPa .87 2.49
Inlet Pressure - the pressure of the gas before it
reaches the oven.
Manifold Pressure - the pressure of the gas as it
enters the main burner(s).
Min - the minimum pressure recommended to oper-
ate the oven.
Max - the maximum pressure at which the manufac-
turer warrants the oven’s operation.
Each oven is supplied with a regulator to maintain the
proper gas pressure. The regulator is essential to the
proper operation of the oven and should not be removed.
It is preset to provide the oven with 3.5” W.C. (0.87 kPa)
for natural gas and 10.0” W.C. (2.50 kPa) for Propane at
the manifold.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS SUPPLY
UNLESS THE INLET PRESSURE IS ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be thor-
oughly purged of all metal lings, shavings, pipe dope,
and other debris. After connection, the oven should be
checked for correct gas pressure.
The oven and its individual shuto󰀨 valve must be discon-
nected from the gas supply piping system during any
pressure testing of that system at test pressures in ex-
cess of 1/2 psig (13.85” W.C., 3.45 kPa).
The oven must be isolated from the gas supply piping
system by closing its individual manual shuto󰀨 valve dur-
ing any pressure testing of the gas piping system at test
pressures equal or less than 1/2 psig (13.85” W.C., 3.45
kPa).
Figure 9
Gas Connection 2.5” (64 mm)
Gas Connection 3.75” (85.7 mm)

Bekijk gratis de handleiding van Blodgett DFG-100, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.