Blodgett CNVX-14G handleiding

54 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 4 van 54
2
Installation
Owners Responsibilities
INSTALLATION RESPONSIBILITIES PRIOR TO SERVICE STARTUP INSPECTION
You are entitled to a free start-up inspection service by our factory ASAP. Before a factory representative arrives to perform
a startup procedure, the owner must already have satised the following requirements.
1. Oven(s) are uncrated, stacked (if applies) and put in place.
NOTE: Please refer to Leg Attachment and Stacking.
Maximum shelf loading - 60 lbs (27.3 Kg)
PLUMBING SPECIFICATIONS
WATER
Water pressure 40 PSI minimum
50 PSI maximum
Water connection 3/4” garden hose for spray hose - Cold water only
Minimum requirements TDS: 40-125 ppm
Hardness: 35-180 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
pH: 7.0-8.5
DRAINAGE
Drain type Atmospheric Vented Drain
Drain connection 2.00” (50.8mm) Copper
Maximum water drain temperature 140ºF (60ºC)
ELECTRICAL RATINGS - CNVX-14G/AA
TYPE OF
GAS
GAS INPUT VOLTAGE PHASE AMPS MOTOR
Natural 65,000 BTU/Hr 115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
Propane 65,000 BTU/Hr 115
208-240
1
1
12
6
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
3/4” NPT connector for all U.S. and Canadian installations
RATINGS - CNVX-14E/AA
VOLTAGE
HZ
KW
PHASE
MAX LOAD (AMPS
MOTOR
L1 L2 L2
208 60 19 3 53 53 50 3/4 HP 208-240VAC, 50/60 Hz
240 60 19 3 46 46 43 3/4 HP 208-240VAC, 50/60 Hz
480 60 19 3 23 23 21 3/4 HP 208-240VAC, 50/60 Hz