Blaupunkt WP8010 handleiding
Handleiding
Je bekijkt pagina 8 van 84

1. Handle 2. Body
3. Base 4. Float cable handle
5. Universal connector 6. Paddle impeller the WP7010 mode / Cutter impeller in the WP8010 mode
Technical data
INSTALLATION
The pump is intended for placement in the sewage systems, water bodies, and flooded rooms for
pumping and transferring dirty water and sewage. Make sure that the float can move freely, is not
blocked by other objects or does not get stuck in the mud.
The device should work in a vertical position.
Make sure that the water can be drained to the desired location (check local regulations) before using
the pump.
WP7010 Supplied with floating switch, plastic outlet + hose connector 1" 1.5" 2", with 20m 0.5mm
thickness hose, WP8010 Supplied with floating switch, plastic outlet + hose connector 1" 1.5" 2", with
30m 0.5mm thickness hose.
Always make sure that the pump, power cord and plug are not damaged before use. Make sure that the
turn-on point and the turn-off point are correctly set. It is worth checking the operation of the pump in
the barrel – whether the pump starts and stops when the float position is changed.
PUMP OPERATION
The attachment of the float cable in the handle determines the turn-on/turn-off height. The upper
position determines when the pump will start operating. The lower position determines the pump
turn-off moment.
Place the pump on a hard surface or use a rope attached to the pump handle to hang it in the reservoir.
Connect the pump to the power supply.
Pump starting and stopping depend on water level and float position.
CLEANING AND MAINTENANCE
Make sure that the pump is disconnected from the power supply before proceeding with maintenance.
If the pump is carried – wash the pump after each use.
When using the pump in one place, it is recommended to clean it once every 3 months.
The accumulated sludge can be washed with a pressure washer. Wipe the components with a cloth. Do
not use aggressive detergents, solvents or sharp objects.
Do not use the pump when the temperature is below 0°. Store the pump in a place where the
temperature is higher than 0°.
It is recommended to use the pump at least once every 3 months.
Specification/Model
Voltage / Rated power
Maximum power
Maximum flow
Maximum head
Maximum working depth
Maximum water temperature
Maximum size of particles/impurities
IPX protection class
WP7010 WP8010
230 V ~ 50 Hz / 550W
750 W 1000 W
17000 l/h 18000 l/h
12 m
14 m
5 m 5 m
40 ºC
3 mm
IPX8
6
WP7010 8010
230 V ~ 50 Hz / 750W
Bekijk gratis de handleiding van Blaupunkt WP8010, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Blaupunkt |
| Model | WP8010 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 7001 MB |