Big Ass Fans Cool-Space 300 handleiding

52 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 15 van 52
WWW.BIGASSFANS.COM © 2020 DELTA T LLC ALL RIGHTS RESERVED.
13
Error codes (Cool-Space® 500 only)
Error Solution(s)
E1 - Voltage Self-Inspection Error
Try a dierent circuit.
Replace the panel.
E2 - Overcurrent Protection
Current draw is too high.
Check extension cord size.
Check that motor spins freely.
Check that airflow is not obstructed.
E3 - Under Voltage Protection
Supply voltage is too low (< 100 V).
Try a dierent circuit.
Install a voltage regulator.
E4 - Over Voltage Protection
Supply voltage is too high (> 130 V).
Try a dierent circuit.
Install a voltage regulator.
E5 - Overload Protection
Motor is running too hot.
Check that airflow is not obstructed.
Check extension cord size.
E6 - Overheat Protection
Check that airflow is not obstructed.
Check for mineral buildup on the motor.
Check extension cord size.
E7 - Panel with Motor Communication Error Check for a broken or loose wire.
E8 - Panel Internal Error Replace the panel.
E9 - Motor No Response
Check for a broken or loose wire.
Replace the motor.
F6 - Panel Communication Error Check for a broken or loose wire.

Bekijk gratis de handleiding van Big Ass Fans Cool-Space 300, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBig Ass Fans
ModelCool-Space 300
CategorieVentilator
TaalNederlands
Grootte3863 MB