13
Error codes (Cool-Space® 500 only)
Error Solution(s)
E1 - Voltage Self-Inspection Error
• Try a dierent circuit.
• Replace the panel.
E2 - Overcurrent Protection
Current draw is too high.
• Check extension cord size.
• Check that motor spins freely.
• Check that airflow is not obstructed.
E3 - Under Voltage Protection
Supply voltage is too low (< 100 V).
• Try a dierent circuit.
• Install a voltage regulator.
E4 - Over Voltage Protection
Supply voltage is too high (> 130 V).
• Try a dierent circuit.
• Install a voltage regulator.
E5 - Overload Protection
Motor is running too hot.
• Check that airflow is not obstructed.
• Check extension cord size.
E6 - Overheat Protection
• Check that airflow is not obstructed.
• Check for mineral buildup on the motor.
• Check extension cord size.
E7 - Panel with Motor Communication Error • Check for a broken or loose wire.
E8 - Panel Internal Error • Replace the panel.
E9 - Motor No Response
• Check for a broken or loose wire.
• Replace the motor.
F6 - Panel Communication Error • Check for a broken or loose wire.
Bekijk gratis de handleiding van Big Ass Fans Cool-Space 300, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Big Ass Fans |
| Model | Cool-Space 300 |
| Categorie | Ventilator |
| Taal | Nederlands |
| Grootte | 3863 MB |