User Manual for WTR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air10
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the
machine to conrm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to unsafe
cabinet temperature when GFI device trips from moisture.
Power Cord
This 115 volt model is equipped with a cord and 5-15P plug.
If the power cord becomes damaged, it must be replaced
with the identical cord.
Follow All National and Local Codes
This unit must be grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the
bottom area, and the inside wall of the cabinet will begin
to become cold.
The cabinet temperature has been set at the factory and
should not need adjustment, however if it was changed,
the standard setting is 38º F.
Cautions
Care must be taken whenever
moving or servicing the unit.
The refrigerant is contained in a
sealed system, but if released it
may be ammable.
ELECTRICAL
CAUTION
IMPORTANT NOTICE
This Cabinet Was Manufactured With
Either A Mechanical Controller, or a
Danfoss™ Or Eliwell™ Brand Electronic
Controller.
Identify Which Controller Is Present
And Refer To The Information For That