User Manual for VM Refrigerators Beverage-Air
Rev. 04/25Beverage-Air10
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the
machine to conrm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to
unsafe cabinet temperature when GFI device trips from moisture.
Power Cord
This 120 volt model is equipped with a cord and either 5-15P
or 5-20P plug.
If the power cord becomes damaged, it must be replaced
with the identical cord.
Follow All National and Local Codes
This Unit Must Be Grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the
top area, and cool air will ow from the inside blower.
The cabinet temperature has been set at the factory at
34°F and should not be adjusted by unqualied personnel.
For any adjustment, you must contact your distributor.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be ammable.
Electronic Temperature Control
The unit is provided with an electronic temperature
control which controls the operation of the unit based on
the temperature of the air entering the evaporator at the
front of the unit. In order to achieve the desired product
temperature, the electronic control is factory adjusted to turn
o the refrigeration system at 35°F and start it at 39.5°F .
When you plug the unit in, the control display will illuminate.
However, there is a start-up delay of two minutes before
the compressor(s) are energized. This delay avoids the
possibility that during a power failure, the compressors
are forced to restart before the refrigerant pressures are
equalized.
The control has been factory-adjusted with a defrosting cycle
scheduled to last 6 minutes every hour to ensure that the
evaporator performs without any ice build-up.
None of the factory-programmed electronic control
parameters can be modied unless an access code is entered
(only your distributor's technical personnel have that code).
ELECTRICAL