Beverage-Air PRT1XTHC-1AS handleiding
Handleiding
Je bekijkt pagina 10 van 28

User Manual for PRI, PRD, and PRT Refrigerators Beverage-Air
Rev. 04/25Beverage-Air10
ELECTRICAL
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the
machine to conrm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Power Cord
This 115 volt model is equipped with a cord and 5-15P plug.
If the power cord becomes damaged, it must be replaced
with the identical cord.
GFCI
Units that utilize variable speed compressor technology
can experience nuisance tripping on Class A GFCI outlets
which have a trip limit of 4 to 6 mA. To avoid this
issue in a location that requires GFCI circuit protection,
Beverage-Air recommends using either an Eaton, SGF20,
or HUBBELL Model Number GFRST83W 20A Heavy Duty
Hospital Grade Self-Test GFCI Receptacle.
Follow All National and Local Codes
This unit must be grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the
top area, and cool air will ow from the inside blower.
The cabinet temperature has been set at the factory and
should not need adjustment, however if it was changed,
the standard setting is 38º F.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be ammable.
After the cabinet has been installed, leveled, and cleaned
as described above, refer to the following checklist:
• Check for proper electrical hook-up.
• Cabinet MUST NOT SHARE A RECEPTACLE with
another piece of equipment
• Check that all clearances are in line with the
aforementioned guidelines.
• Check that cabinet is level.
* NOTE: Once the unit has been started and reaches proper
storage temperatures, it may be loaded with product. For
proper energy eciency and airow we recommend a
minimum1” clearance between product and side walls, 4”
clearance between product and ceiling, and 1” clearance
from the bottom of the unit.