PROBLEM POSSIBLE CAUSE REMEDY
Cabinet not operating Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker
Power cord unplugged Plug in power cord to designated receptacle.
Cabinet cannot share same outlet with other
equipment.
Improper voltage supplied to cabinet
(voltage does not match Data-Plate).
Correct supply voltage (remove extension cords or
other equipment on circuit, etc)
Main power switch and/or controller
turned o
Turn on main power switch and/or controller.
Defective high limit/heater safety switch Internal high limit/heater safety may be defective.
Contact the factory or an authorized service
provider for further assistance if all else has
been checked above and the cabinet is still not
operating.
Cabinet not holding
temperature
Cabinet not pre-heated before use Turn cabinet on one (1) hour before use
Prolonged door opening of door ajar Make sure door is closed when not in use. Avoid
prolonged door openings.
Door gasket not sealing properly Check door gasket condition Adjust door or
replace gasket.
Controller setpoint is too low Adjust controller setpoint to a higher temperature
Improper voltage supplied to cabinet
(voltage match Data-Plate )
Correct supply voltage (remove extension cords or
does not) other equipment on circuit, etc).
Product load held too long Hold product load inside cabinet per recommended
temperature. Examples of holding times and
temperatures are on page 13.
Blower motor not operating or air duct is
air duct is restricted,
Check blower motor and air duct for proper air
ow. Try to carefully locate and remove the cause
of air restriction. If further assistance is restricted
required, contact the factory or authorized service
provider for further assistance.
Heater elements not operating Carefully check heater elements for proper
operation .If heating element(s) are not working
properly, contact the factory or an authorized
service provider for further assistance.
Cabinet is overheating. Defective high limit/heater safety switch If controller setpoint is adjusted to a lower setting
and the internal cabinet temperature exceeds
+200' F, turn o cabinet and contact the factory
or an authorized service provider for further
assistance
Defective blower motor Check blower motor operation. If blower motor is
not operating, contact the factory or an authorized
service provider.