- Th
e outlet or the system is equipped with an efficient ground connection in
accordance with the current legal standards and regulations. The company will not
b
e responsible for the non-compliance with these instructions.
letter L (phase) =
brown wire;
letter N (neutral) = blue wire;
ground symbol
= green-yellow wire;
- The power cord must be positioned so that an over temperature of 75 K will not be
r
eached at any po
int.
-
Do not use reductions, adapters or splitters since they might cause false contac
ts
an
d lead to dangerous overhe
ating.
Wh
en the connection is made directly to the electric network:
- Use a device that ensures disconnection from the mains in which the contacts are
opened to a distance that permits complete disconnection according to
the
c
onditions for over-voltage category
III.
- R
emember that the ground wire must not be interrupted by the circuit-breaker.
-
As
an alternative, the electric connection can also be protected by a high-sensitivity
residual current circuit-breaker.
-
It
is highly recommended to attach the special green-yellow ground wire to
an
effic
ient ground syst
em.
WARN
ING: If the power cord is replaced, the ground wire (yellow-green) connec
ted
to
the terminal, should be longer than the other wires by about 2
cm.
WARN
ING: The power cord should be replaced only by qualified person
nel.
Types of power cords The appliance is equipped with a terminal for the electric connection placed behind,
which is accessible by removing the posterior casing.
The power supply cable is suitable for appliance operating on 220-240 V~
ATTENTION: The appliance conforms with the current national
Regulations (Gas Directive) regarding gas appliances for domestic use and
the like, Current national Regulations (Low Voltage Directive) regarding
electrical safety and Current national Regulations, (EMC Directive)
regarding electromagnetic compatibility. Ensure that the electricity supply is
switched off before making the connection. This appliance must be earthed.
Connection to the electricity supply must be made through the flex cable that is
already attached to the rear of the cooker. The end of the cable is tucked into
the cooker storage area.
Connection to the supply must be made through fixed wiring. It cannot be connected
to a normal domestic power socket. A double pole switched cooker box should be
used with contact separation of at least 3mm.
Turn on each hob zone to check that all elements are functioning correctly. Remove
all packaging and combustible items from the oven. Turn on the oven selector switch
and thermostat knob to check that the oven is functional on all modes.
Adaptation to different Before performing any maintenance operation, disconnect the appliance from
types of gas the gas supply and electricity network.
Replacing the gas nozzles to operate with another type of gas:
Follow the instructions below to change the burner nozzles on the work
surf
ace:
- Isolate the appliance from the electric outlet to avoid
any
ty
pe of electric contact.
-
Remove the grids from the work surface.
-
R
emove the burners.
-
Unscrew the nozzles using a 7 mm spanner, and replac
e
th
em (Fig.4) with those needed for the new type of
gas accordingly.
Fig 4