The up-stand is packed separate and is taped to the back of the cooker. Other
components can be found inside the ovens. All packaging and covering films must
be removed before the installation can commence.
All electric cookers should be installed by a qualified electrician in accordance with
IEE regulations and local electricity provider rules. Building regulations must be
considered when undertaking any installation. Failure to install the appliance
correctly will render the warranty null and void.
Range cookers are heavy and should be handled by two people. Never lift or drag a
range by the oven handles as damage may occur.
Note: Pictures and graphics in this manual cover different models and may vary in
minor details from your cooker.
INSTALLING RANGE COOKER
Rating of Services The rating plate is visible in the storage area of the cooker and a copy is also
attached to last page of the user manual.
Before connecting the cooker, check that the requirements on the rating plate
correspond with those of the electrical system and gas supply (where applicable).
Ensure that the electrical system and isolating switches have a suitable capacity to
carry the maximum power as indicated on the rating plate.This chart can be used as
a guide to the electrical supply ratings.
ELECTRICAL SUPPLY CABLE AND MCB SIZE FOR DEDICATED COOKER CIRCUIT
Cooker model
220-240 V~
380-415 V2N ~
380-415 V3N ~
90x60 single oven Induction hob top
3x10 mm² MCB 63A
4x4 mm² MCB 32A
5x1,5 mm² MCB 16A
90x60 twin oven Induction hob top*
3x6 mm² MCB 40A
4x4 mm² MCB 32A
5x2,5 mm² MCB 25A
100x60 twin oven Induction hob top*
3x6 mm² MCB 40A
4x4 mm² MCB 32A
5x2,5 mm² MCB 25A
100/110x60 3 oven compartments
Induction hob top
3x10 mm² MCB 63A
4x6 mm² MCB 40A
5x4 mm² MCB 32A
* With diversity factor applied
Positioning The cooker may be installed in a kitchen or open-plan kitchen diner but not in a
room containing a bath or shower. The cooker should be positioned in an area with
good light and free from draughts.
Any shelf or unit of combustible material should be at least 660mm above the
hotplate. In addition an area of 75mm wide on either side and behind the hotplate
must be clear of any combustible materials to a height of 400mm. Units must not
overhang over the hob.
Kitchen cabinets may be fitted flush to the sides of the cooker, but to allow for
cleaning and servicing
It is recommended that a 2.5mm gap be allowed on each side so that the cooker
may be moved if necessary.
The worktop or kitchen cabinets must not protrude beyond the height of the cooker
hotplate frame.
Ventilation Your appliance is not connected to a combustion products evacuation device. Th
e room in which it is to be installed must have an air supply in accordance with
national standards. The room must have an opening window or equivalent, and
some rooms may require a permanent vent in addition to the opening window.