IX. SERVICE
CAUTION: ELECTRIC SHOCK HAZARD Disconnect power
whenever servicing unit. More than one disconnect may
be required to de-energize unit.
Any service performed on the Architectural Icon Series air curtain
MUST be done by qualied personnel. Berner air curtains require
very little servicing. All parts are easily accessible for periodic
inspection and maintenance. Units should be cleaned at least
twice a year. Your particular application (the amount of dirt and
dust in the air) and location of the unit(s) will determine how
often your unit(s) will need to be cleaned and serviced. All
motors have permanently lubricated, sealed, sleeve bearings
and require no maintenance.
Figure 10 - Bottom Access Panel Removal
VIII. MAINTENANCE & CLEANING
CAUTION: ELECTRIC SHOCK HAZARD Disconnect power
whenever servicing unit. More than one disconnect may be
required to de-energize unit.
Stainless steel appliance wipes are recommended for
wiping down both the bottom panel and the cabinet.
Keep your air curtain operating at peak eciency by cleaning
the blower wheels, motor(s) and intake screen. Buildup of dust
on the blower wheels can cause vibration, noise and excessive
wear on the motor bearings. The frequency of cleaning will
depend on the environment where the unit is operating.
Dirty, dusty or greasy environments could require a cleaning
schedule of once every month. If the environment is not that
dirty, the unit(s) should be scheduled for cleaning a minimum
of once every six months. The air inlet lter typically requires
cleaning every three to six months.
A. PERFORMING PREVENTIVE MAINTENANCE
1. Disconnect the power to the unit.
2. Filter - the aluminum washable lter is held in by
the inlet screen. Access the lter by removing the
Phillips head ush mount screws across the top front
of the unit. Rotate the inlet screen forward slightly to
allow its tabs to be removed from the bottom front
cover. Vacuum and/or wash with dish soap and water.
3. Internal - open the bottom access panel by removing
the inlet screen as described above, and then
removing the now exposed fasteners across
the front of the bottom panel, and the two screws
along the bottom left and right side. The panel is
hinged, so carefully allow it to swing down. Vacuum
and scrape (if necessary) to remove the build-up of dirt
and debris. The motor(s) are permanently lubricated
and require no additional lubrication.
4. Re-install the bottom access panel and intake screen.
See Figure 10.
5. Switch the power on after cleaning.
CAUTION: STAND CLEAR OF THE UNIT OR WEAR SAFETY
GOGGLES AS LOOSE DEBRIS MAY BE PRESENT AND MAY EXIT
THE NOZZLE UPON START UP!
INLET SCREEN
SUB ASSEMBLY
BOTTOM
ACCESS PANEL
SUB ASSEMBLY