II. MOUNTING INSTRUCTIONS (General)
INDOOR MOUNTING ONLY -
The Architectural Contour Air Curtain is designed to be an
eective barrier against cold drafts in the winter, hot air in the
summer, ying insects, and airborne contaminants.
To achieve optimum protection, the air curtain should be
mounted on the inside of the building, ush to the wall and
as close to the top of the door opening as possible. To ensure
peak performance, keep the air stream free of obstructions.
The air curtain will not perform properly if negative air
pressure exists in the building. Under these conditions,
a means for makeup air to the building must be provided
so that the air pressure on both sides of the opening is in
balance.
Before mounting the air curtain, check the supporting structure
to verify that it has sucient load-carrying capacity to support
the weight of the air curtain(s). The mounting hardware
(supplied by others) should be capable of supporting a
minimum of three (3) times the weight of the air curtain.
See Table 1.
IMPORTANT: A minimum of 4” is required above the top rear
corner of the air curtain for the installation and removal of the
inlet screen, and to ensure proper airow.
A. When determining the mounting location for the air
curtain(s), make sure that nothing interferes with the
curtain of air developed when the discharge vanes are
directed from 0° to 20° toward the door opening. If the
air stream strikes any obstruction (the top edge of the
doorway, a door opening device, etc.), the eectiveness
of the air curtain will be greatly reduced. See Figure 2.
B. For optimum performance, the bottom of the air curtain
(discharge nozzle) should be no more than 1” above the
top of the door opening with the air curtain(s) mounted
ush to the wall. If the air curtain must be mounted
higher, it must be spaced out from the wall 3/8” for
every inch the air curtain is above the door opening. See
Figure 3. For optimum protection, any void between the
air curtain and the wall should be sealed along the full
length of the air curtain.
C. Do not block (obstruct) the air intake screen. Insucient
airow can cause the unit to overheat.
D. The air curtain(s) shall:
1. Have a minimum clearance of at least 4” from
the sides and 4" from the top.
2. Have a minimum clearance of at least 6’ between
the bottom of the air curtain and the oor.
3. Be installed Indoors Only.
E. Proceed to either Section III - WALL MOUNTING or
Section IV - SUSPENDED MOUNTING
Figure 2 - General Mounting
Figure 3 - Wall Mounting Location
TABLE 1 - Weight Chart
1¾”
20°
AIR
Discharge
Nozzle
A
I
R
A
I
R
INTERIOR
EXTERIOR
6' minimum
AIR
Airstream
4" minimum
side & top
clearance from
combustible
material
MODEL
Net Weight
MODEL
Net Weight
AC10
Ambient
AC10
Electric
AC10
Hot
Water
AC08
Ambient
AC08
Electric
AC08
Hot
Water
AC10-E-1036A 82 88 107 AC08-E-1036
55 60 75
AC10-E-1042A 91 97 119 AC08-E-1042
61 66 84
AC10-E-1048A 107 113 138 AC08-E-1048
68 73 93
AC10-E-2060A 136 145 173 AC08-E-1060
82 87 11 2
AC10-E-2072A 164 176 210 AC08-E-1072
95 105 133
AC10-E-2084A 182 194 234 AC08-E-2084
123 133 166
AC10-E-2096A 214 226 272 AC08-E-2096
136 146 184
AC10-E-3108A 246 264 310 AC08-E-2108
150 160 203
AC10-E-3120A 264 282 332 AC08-E-2120
164 174 221
AC10-E-3132A 273 291 352
AC10-E-3144A 321 339 406