Installation
6003417_a – 26.09.2017
EN
3.4.6 Establish electrical power supply
Observe the voltage specifications on the rating plate.
Plug the connecting cable mains plug into the socket.
Route the cable such that it is not kinked, crushed or
damaged and so that it will not get in the way when
replacing the filter filling.
Make sure the device can be disconnected from the
electricity supply after installation.
3.4.7 Installing the recirculated air filter permalyt
Connect the recirculated air filter permalyt as follows:
y Wire 1 on terminal 1
y Wire 2 on terminal 2
Plug the cold device plug into the socket on the fan
housing.
A connection check takes place automatically:
y If the device is not connected correctly, five beeps will
sound.
Correct the connection of the wires to terminals 1 and
2.
y If the device is connected correctly, three will beeps
sound.
Insert the recirculated air filter permalyt.
Lay the cable from the recirculated air filter permalyt
through the guide channel.