Operation
6005077_a – 24.02.2020
4.2.2 Extraction mode / recirculated air mode
changeover
If the device is configured for hybrid mode, it is possible to
switch between extraction mode and recirculated air mode
at any time after activating the changeover function.
The changeover function is activated in configuration mode.
D “4.3 Configuring the device” (page 22).
Button Function
If the changeover function is activated:
☞ Touch the button one time.
Button glows dimly:
y The device operates in extraction mode.
y The wall box is opened.
y The cleaned air is discharged outdoors.
Button glows brightly:
y The device is operating in recirculated air
mode.
y The wall box is closed.
y The cleaned air is discharged into the
room.
4.2.3 Filter filling indicator
The device has a control indicator to remind the operator
to change the filter filling. If no air circulation filter is used,
the control indicator has no meaning.
The function is set so that the button flashes every 1,000 fan
operating hours (flash duration 120 seconds) as soon as
the device is turned off. The hours counter is restarted by
switching off the control indicator.
Button Function
Button flashes:
The filter filling must be replaced.
D “6.2.2 Replacing filter filling (with
recirculating and hybrid mode)”
(page 25).
☞ Hold the button (> 1 second) to restart the
hours counter.
4.2.4 Window contact switch
If a window contact switch is connected to the device, this
monitors whether the corresponding window is open or
closed. Extraction only takes place with an open window or
in recirculated air mode.
Button Function
Button flashes:
y A window contact switch is connected to
the device.
y The window is closed.
y The device does not perform extraction.
☞ Open the window.
y Extraction can be used.
4.2.5 Cooktop lighting
The cooktop lighting is dimmable and is equipped with
energy-saving LEDs. The lighting can be used independently
of the fan. It can be switched on when the device is on.
It can be switched off at any time.
Button Function
Dimmer.
☞ Press the button once to switch the
cooktop lighting on or off.
☞ Hold the button (more than 1 second)
to start the dimmer. After releasing the
button, the cooktop lighting remains at
the selected brightness.
After switching off, the cooktop lighting
starts with full brightness the next time it is
switched on.