16
Nozzle change operation
1. Please use driver with special head for removed and install nozzle as.
(gure 3)
2. Please remove nozzle (gure 4) from burner with special nozzle driver
and install new nozzle. (gure 5)
Ventilation of room
The air needed for burning is received from room air and the gases emitted
are given directly in room. For safe operation of your product, good room
ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However,
room has a door opening outside, it is no needed to vent holes.
Room size Ventilating opening
Smaller than 5 m³ min. 100 cm²
Between 5 m³ - 10 m³ min. 50 cm²
Bigger than 10 m³ no need
In basement or cellar min. 65 cm²
Figure 3
Figure 4
Figure 5
GB