BEKO FBSHT62111GX handleiding
Handleiding
Je bekijkt pagina 24 van 104

EN / 24
The fixed ventilation opening can include
openings for existing airbricks, extraction
hood ducting opening dimension etc.
Total gas consumption
(kW)
Min. ventilation opening
(cm2)
0-2 100
2-3 120
3-4 175
4-6 300
6-8 400
8-10 500
10-11,5 600
11,5-13 700
13-15,5 800
15,5-17 900
17-19 1000
19-24 1250
Rooms that do not have openable doors
and/or windows that open directly to the
outer environment
If the room where the appliance is installed
does not have a door and/or a window that
opens directly to the external environment,
other products shall be sought that defin-
itely provide a fixed non-adjustable and
non-closable ventilation opening which
meets the total minimum ventilation open-
ing requirements for the total gas con-
sumption of the appliance as indicated in
the above table. Also the appropriate build-
ing regulations advise should be followed.
Where a room or internal space contains
more than one gas appliance, additional
ventilation area shall be provided on top of
the requirement given in the table above.
Size of additional ventilation area shall be
appropriate to regulations of other gas ap-
pliances.
There should also be a minimum clearance
of 10mm on the bottom edge of the door
that opens to the inner environment in the
room where the appliance is installed. You
must ensure that items such as carpets
and other floor coverings etc., do not affect
the clearance when the door is closed.
The cooker may be located in a kitchen, kit-
chen/diner or a bed-sitting room, but not in
a room containing a bath or a shower. The
cooker must not be installed in a bed-sit-
ting room of less than 20 m3.
Do not install this appliance in a room be-
low ground level unless it is open to ground
level on at least one side.
4.2 Electrical connection
General warnings
• Disconnect the product from the electric
connection before starting any work on
the electrical installation. There is an
electric shock hazard.
• Connect the product to a grounded out-
let/line protected by a miniature circuit
breaker of suitable capacity as stated in
the "Technical specifications" table. Have
the grounding installation made by a
qualified electrician while using the
product with or without a transformer.
Our company shall not be liable for any
damages that will arise due to using the
product without a grounding installation
in accordance with the local regulations.
• The product can only be connected to the
mains electricity connection by an au-
thorized and qualified person, and the
warranty of the product starts only after
correct installation. The manufacturer
cannot be held responsible for any dam-
ages that may arise due to operations by
unauthorized persons.
• The electric cable must not be crushed,
folded, jammed or touch hot parts of the
product. If the electric cable is damaged,
it must be replaced by a qualified electri-
cian. Otherwise there is an electric shock,
short circuit or fire hazard!
• The mains supply data must correspond
to the data specified on the type label of
the product. The rating plate is either
seen when the door or the lower cover of
the appliance is opened or it is located at
the rear wall of the appliance depending
on the appliance type.
EN
RO
Bekijk gratis de handleiding van BEKO FBSHT62111GX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | BEKO |
Model | FBSHT62111GX |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 11241 MB |