Split type air conditioner / User Manual
9 / EN
cause fire, and may also cause
shock. All electrical connections
must be made according to the
Electrical connection diagram
located on the panels of the
indoor and outdoor units.
•
All wiring must be properly
arranged to ensure that the
control board cover can close
properly. If the control board
cover is not closed properly, it
can lead to corrosion and cause
the connection points on the
terminal to heat up, catch fire,
or cause electrical shock.
•
If connecting power to
fixed wiring, an all-pole
disconnection device which
has at least 3mm clearances
in all poles, and have a
leakage current that may
exceed 10mA, the residual
current device (RCD) having
a rated residual operating
current not exceeding 30mA,
and disconnection must be
incorporated in the fixed wiring
in accordance with the wiring
rules.
Take note of fuse
specications
The air conditioner’s circuit
board (PCB) is designed with
a fuse to provide overcurrent
protection. The specifications
of the fuse are printed on the
circuit board ,such as:
T3.15AL/250VAC,
T5AL/250VAC, T3.15A/250VAC,
T5A/250VAC, T20A/250VAC,
T30A/250VAC,etc.
C
Note: For the units
using R32 or R290
refrigerant , only the
blast-proof ceramic
fuse can be used.
1 Safety precautons