• Before using the recovery machine, check that it is in
satisfactory working order, has been properly maintained
and that any associated electrical components are sealed
to prevent ignition in the event of a refrigerant release.
• Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the
refrigerant supplier in the correct recovery cylinder, and the
relevant Waste Transfer
Note arranged.
• Do not mix refrigerants in recovery units and especially not
in cylinders.
• If compressors or compressor oils are to be removed,
ensure that they have been evacuated to an acceptable
level to make certain that flammable refrigerant does not
remain within the lubricant.
The evacuation process shall be carried out prior to
returning the compressor to the suppliers.
• Only electric heating to the compressor body shall be
employed to accelerate this process.
• When oil is drained from a system, it shall be carried out
safely.
• When moving or relocating the air conditioner, consult
experienced service technicians for disconnection and
reinstallation of the unit
• Do not place any other electrical products or household
belongings under indoor unit or outdoor unit. Condensation
dripping from the unit might get them wet, and may cause
damage or malfunction of your property.
• Do not use means to accelerate the defrosting process or
to clean, other than those recommended by the
manufacturer.