6-6 No ignition sources
• No person carrying out work in relation to a refrigeration
system which involves exposing any pipe work that
contains or has contained flammable refrigerant shall use
any sources of ignition in such a manner that it may lead to
the risk of fire or explosion
All possible ignition sources, including cigarette smoking,
should be kept sufficiently far away from the site of
installation, repairing,removing and disposal, during which
flammable refrigerant can possibly be released
to the surrounding space.
• Prior to work taking place, the area around the equipment
is to be surveyed to make sure that there are no flammable
hazards or ignition risks. “No Smoking” signs shall be
displayed.
6-7 Ventilated area
• Ensure that the area is in the open or that it is adequately
ventilated before breaking into the system or conducting
any hot work.
A degree of ventilation shall continue during the period
that the work is carried out.
The ventilation should safely disperse any released
refrigerant and preferably expel it externally into the
atmosphere.
6-8 Checks to the refrigeration equipment
• Where electrical components are being changed, they
shall be fit for the purpose and to the correct specification.
At all times the manufacturer's maintenance and service
guidelines shall be followed. If in doubt consult the manu
facturer's technical department for assistance.