1. To guarantee the unit work normally, please read the
manual carefully before installation, and try to install strictly
according to this manual.
2. Do not let air enter the refrigeration system or discharge
refrigerant when moving the air conditioner.
3. Properly ground the air conditioner into the earth.
4.Check the connecting cables and pipes carefully, make
sure they are correct and firm before connecting the power
of the airconditioner.
5.There must be an air-break switch.
6. After installing, the consumer must operate the air condi
tioner correctly according to this manual, keep a suitable
storage for maintenance and moving of the air conditioner
in the future.
7. Fuse of indoor unil:T3.15A 250VAC or T5A 250VAC.
Please refer to the screen printing on the circuit board for
the actual parameters, which must be consistent with the
parameters on the screen printing.
8. For 5K~13K models, fuse of outdoor unit:T15A 250VAC
or T 20A 250VAC. Please refer to the screen printing on the
circuit board for the actual parameters, which must becon
sistent with the parameters on the screen printing
9. For 14K-18K models, fuse of outdoor unit: T 20A
250VAC.
10. For 21 K~36K models, fuse of outdoor unit: T 30A
250VAC.
11. The installation instructions for appliances that are
intended to be permanently connected to fixed wiring, and
have a leakage current that may exceed 10 mA, shall state
that the installation of a residual current device (RCD)
having a rated residual operating current not exceeding 30
mA is advisable.