• Intrinsically safe components are the only types that can be
worked on while live in the presence of a flammable
atmosphere. The test apparatus shall be at the correct rating.
• Replace components only with parts specified by the
manufacturer. Other parts may result in the ignition of
refrigerant in the atmosphere from a leak.
9.Cabling
• Check that cabling will not be subject to wear, corrosion,
excessive pressure, vibration, sharp edges or any other
adverse environmental effects.
The check shall also take into account the effects of aging
or continual vibration from sources such as compressors or
fans.
10.Detection of flammable refrigerants
• Under no circumstances shall potential sources of ignition
be used in the searching for or detection of refrigerant leaks.
A halide torch (or any other detector using a naked flame)
shall not be used
11.Leak detection methods
The following leak detection methods are deemed
acceptable for systems containing flammable refrigerants:
–Electronic leak detectors shall be used to detect flammable
refrigerants, but the sensitivity may not be adequate, or may
need re-calibration. (Detection equipment shall be calibrated
in a refrigerant-free area.)
–Ensure that the detector is not a potential source of ignition
and is suitable for the refrigerant used.
–Leak detection equipment shall be set at a percentage of
the LFL of the refrigerant and shall be calibrated to the refrig
erant employed and the appropriate percentage of gas (25 %
maximum) is confirmed.