BEKO BSVOL 090 handleiding

59 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 26 van 59
The following checks shall be applied to installations using
flammable refrigerants:
–The charge size is in accordance with the room size within
which the refrigerant containing parts are installed;
–The ventilation machinery and outlets are operating
adequately and are not obstructed;
–If an indirect refrigerating circuit is being used, the
secondary circuit shall be checked for the presence of
refrigerant;
–Marking to the equipment continues to be visible and
legible. Markings and signs that are illegible shall be
corrected;
–Refrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance
which may corrode refrigerant containing components,unless
the components are constructed of materials which are
inherently resistant to being corroded or are suitably
protected against being so corroded.
6-9 Checks to electrical devices
• Repair and maintenance to electrical components shall
include initial safety checks and component inspection
procedures.
• If a fault exists that could compromise safety, then no
electrical supply shall be connected to the circuit until it is
satisfactorily dealt with.
• If the fault cannot be corrected immediately but it is
necessary to continue operation, an adequate temporary
solution shall be used.
This shall be reported to the owner of the equipment so all
parties are advised.
• Initial safety checks shall include:
–That capacitors are discharged: this shall be done in a
safe manner to avoid possibility of sparking;
10