Split type air conditioner / User Manual 27 / 108 EN
26 / 112 EN
Split Type Air Conditioner / User Manual
A
WARNING! All wiring must be
performed strictly in accordance
with the wiring diagram located
on the back of the indoor unit’s
front panel.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Facing the back of the unit, remove the plastic
panel on the bottom left-hand side.
5. Feed the signal wire through this slot, from the
back of the unit to the front.
6. Facing the front of the unit, connect the wire
according to the indoor unit’s wiring diagram,
connect the u-lug and firmly screw each wire
to its corresponding terminal.
A
CAUTION! Do not mix up
live and null wires. This is
dangerous, and can cause
the air conditioning unit to
malfunction.
7. After checking to make sure every connection
is secure, use the cable clamp to fasten the
signal cable to the unit. Screw the cable clamp
down tightly.
8. Replace the wire cover on the front of the unit,
and the plastic panel on the back.
C
The wiring connection process
may differ slightly between units
and regions.
Step 7: Wrappiping and cables
Before passing the piping, drain hose, and the
signal cable through the wall hole, you must
bundle them together to save space, protect
them, and insulate them (Not applicable in North
America).
1. Bundle the drain hose, refrigerant pipes, and
signal cable as shown below:
Indoor Unit
Space behind unit
Refrigerant piping
Drain hose
Signal wire
Insulation tape
Indoor Unit
Signal wire
Drain hose
Insulation tape
Refrigerant piping
Space behind unit
C
Make sure that the drain hose
is at the bottom of the bundle.
Putting the drain hose at the
top of the bundle can cause the
drain pan to overflow, which can
lead to fire or water damage.
A
CAUTION! While bundling these
items together, do not intertwine
or cross the signal cable with
any other wiring.
2. Using adhesive vinyl tape, attach the drain
hose to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire,
refrigerant pipes, and drain hose tightly
together. Double-check that all items are
bundled.
A
CAUTION! When wrapping the
bundle, keep the ends of the
piping unwrapped. You need to
access them to test for leaks
at the end of the installation
process (refer to Electrical
Checks and Leak Checks section
of this manual).
4 Installation
27 / 112 EN
Split Type Air Conditioner / User Manual
Step 8: Mount indoor unit
If you installed new connective piping to the
outdoor unit, do the following:
1. If you have already passed the refrigerant piping
through the hole in the wall, proceed to Step 4.
2. Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
4. Hook the top of the indoor unit on the upper
hook of the mounting plate.
5. Check that unit is hooked firmly on mounting
by applying slight pressure to the left and
right-hand sides of the unit. The unit should
not jiggle or shift.
6. Using even pressure, push down on the bottom
half of the unit. Keep pushing down until the
unit snaps onto the hooks along the bottom of
the mounting plate.
7. Again, check that the unit is firmly mounted
by applying slight pressure to the left and the
right-hand sides of the unit.
If refrigerant piping is already embedded in the
wall, do the following:
1. Hook the top of the indoor unit on the upper
hook of the mounting plate.
2. Use a bracket or wedge to prop up the unit,
giving you enough room to connect the
refrigerant piping, signal cable, and drain hose.
Wedge
3. Connect drain hose and refrigerant piping
(refer to Refrigerant Piping Connection section
of this manual for instructions).
4. Keep pipe connection point exposed to perform
the leak test (refer to Electrical Checks and
Leak Checks section of this manual).
5. After the leak test, wrap the connection point
with insulation tape.
6. Remove the bracket or wedge that is propping
up the unit.
7. Using even pressure, push down on the bottom
half of the unit. Keep pushing down until the
unit snaps onto the hooks along the bottom of
the mounting plate.
C
Keep in mind that the hooks
on the mounting plate are
smaller than the holes on the
back of the unit. If you find that
you don’t have ample room to
connect embedded pipes to
the indoor unit, the unit can be
adjusted left or right by about
30-50 mm (1.18-1.95in),
depending on the model.
Move to left or right
30-50mm
(1.18-1.95in)
30-50mm
(1.18-1.95in)
Move to left or right
30-50mm (1.18-
1.95in)
30-50mm (1.18-
1.95in)
4 Installation