Split type air conditioner / User Manual 25 / 108 EN
24 / 112 EN
Split Type Air Conditioner / User Manual
drain hose.
Wrap the connection point firmly with Teflon
tape to ensure a good seal and to prevent
leaks.
For the portion of the drain hose that will re-
main indoors, wrap it with foam pipe insulation
to prevent condensation.
Remove the air filter and pour a small amount
of water into the drain pan to make sure that
water flows from the unit smoothly.
C
Make sure to arrange the drain
hose according to the following
figures.
CORRECT
Make sure there are no kinks
or dent in drain hose to ensure
proper drainage.
NOT CORRECT
Kinks in the drain hose
will create water traps.
NOT CORRECT
Do not place the end of the
drain hose in water or in
containers that collect water.
This will prevent proper
drainage.
NOT CORRECT
Kinks in the drain hose
will create water traps.
CORRECT
Make sure there are no kinks or
dent in drain hose to ensure proper
drainage.
NOT CORRECT
Kinks in the drain hose will create
water traps.
NOT CORRECT
Kinks in the drain hose will create
water traps.
NOT CORRECT
Do not place the end of the drain
hose in water or in containers that
collect water. This will prevent
proper drainage.
Plug the unused drain hole. To
prevent unwanted leaks you
must plug the unused drain
hole with the rubber plug
provided.
4.2.3 Before performing any electrical
work, read these regulations
1. All wiring must comply with local and national
electrical codes, regulations and must be
installed by a licensed electrician.
2. All electrical connections must be made
according to the Electrical Connection Diagram
located on the panels of the indoor and
outdoor units.
3. If there is a serious safety issue with the power
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
4. Power voltage should be within 90-110% of
rated voltage. Insufficient power supply can
cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, a surge
protector and main power switch should be
installed.
6. If connecting power to fixed wiring, a switch
or circuit breaker that disconnects all poles
and has a contact separation of at least 1/8in
(3mm) must be incorporated in the fixed
wiring. The qualified technician must use an
approved circuit breaker or switch.
7. Only connect the unit to an individual branch
circuit outlet. Do not connect another appliance
to that outlet.
8. Make sure to properly ground the air
conditioner.
4 Installation
25 / 112 EN
Split Type Air Conditioner / User Manual
9. Every wire must be firmly connected. Loose
wiring can cause the terminal to overheat,
resulting in product malfunction and possible
fire.
10. Do not let wires touch or rest against
refrigerant tubing, the compressor, or any
moving parts within the unit.
11. If the unit has an auxiliary electric heater,
it must be installed at least 1 meter (40in)
away from any combustible materials.
12. To avoid getting an electric shock, never
touch the electrical components soon after
the power supply has been turned off. After
turning off the power, always wait 10 minutes
or more before you touch the electrical
components.
A
WARNING! Before performing
any electrical Or wiring work,
turn off the Main power to the
system.
Step 6: Connect signal and power cables
The signal cable enables communication
between the indoor and outdoor units. You must
first choose the right cable size before preparing
it for connection.
Cable Types
Indoor Power Cable (if applicable): H05VV-F or
H05V2V2-F
Outdoor Power Cable: H07RN-F or H05RN-F
Signal Cable: H07RN-F
C
In North America, choose the
cable type according to the local
electrical codes and regulations.
Minimum Cross-Sectional Area of Power and
Signal Cables (For reference) (Not applicable for
North America)
Rated Current of
Appliance (A)
Nominal Cross-
Sectional Area
(mm²)
> 3 and ≤ 6
0.75
> 6 and ≤ 10
1
> 10 and ≤ 16
1.5
> 16 and ≤ 25
2.5
> 25 and ≤ 32
4
> 32 and ≤ 40
6
The size of the power supply cable, signal cable,
fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate
to choose the right cable, fuse, or switch.
C
In North America, please choose
the right cable size according to
the Minimum Circuit Ampacity
indicated on the nameplate of
the unit.
1. Open front panel of the indoor unit.
2. Using a screwdriver, open the wire box cover
on the right side of the unit. This will reveal the
terminal block.
Terminal block
Wire cover
Screw
Cable clamp
Terminal block
Wire cover
Screw
Cable clamp
4 Installation