Split type air conditioner / User Manual 17 / 108 EN
16 / 112 EN
Split Type Air Conditioner / User Manual
3 Unit specifications and features
3.2 Operating temperature
When your air conditioner is used outside of
the following temperature ranges, certain safety
protection features may activate and cause the
unit to disable.
3.3 Inverter Split type
COOL mode HEAT mode DRY mode
Room Temperature 17°C - 32°C (62°F - 90°F)
0°C - 30°C (32°F
- 86°F)
10°C - 32°C (50°F -
90°F)
Outdoor
Temperature
0°C - 50°C (32°F - 122°F)
-15°C - 30°C (5°F
- 86°F)
0°C - 50°C (32°F -
122°F)
-15°C - 50°C (5°F - 122°F) (For models
with low temp. cooling systems.)
0°C - 52°C (32°F - 126°F) (For special
tropical models)
0°C - 52°C (32°F -
126°F) (For special
tropical models)
C
For outdoor units with auxiliary
electric heater. When outside
temperature is below 0°C
(32°F), we strongly recommend
keeping the unit plugged in
at all time to ensure smooth
ongoing performance.
3.4 Fixed-speed type
COOL mode HEAT mode DRY mode
Room Temperature 17°C-32°C (62°F-90°F)
0°C-30°C
(32°F-86°F)
10°C-32°C (50°F-90°F)
Outdoor
Temperature
18°C-43°C (64°F-109°F)
-7°C-24°C
(19°F-75°F)
11°C-43°C
(52°F-109°F)
-7°C-43°C (19°F- 109°F) (For models
with low-temp cooling systems)
18°C-43°C
(64°F-109°F)
18°C-52°C (64°F -126°F) (For special
tropical models)
18°C-52°C (64°F-
126°F) (For special
tropical models)
17 / 112 EN
Split Type Air Conditioner / User Manual
C
Room relative humidity less
than 80%. If the air conditioner
operates in excess of this
figure, the surface of the
air conditioner may attract
condensation. Please sets the
vertical air flow louver to its
maximum angle (vertically to the
floor), and set HIGH fan mode.
To further optimize the performance of your
unit, do the following
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and
TIMER OFF functions.
• Do not block air inlets or outlets.
• Regularly inspect and clean air filters.
A guide on using the infrared remote is not
included in this literature package. Not all the
functions are available for the air conditioner,
please check the indoor display and remote
control of the unit you purchased.
3.5 Other features
• Auto-Restart(some units)
If the unit loses power, it will automatically restart
with the prior settings once power has been
restored.
• Anti-mildew (some units)
When turning off the unit from COOL, AUTO
(COOL), or DRY modes, the air conditioner will
continue operate at very low power to dry up
condensed water and prevent mildew growth.
• Wireless Control (some units)
Wireless control allows you to control your air
conditioner using your mobile phone and a
wireless connection.
For the USB device access, replacement,
maintenance operations must be carried out by
professional staff.
• Louver Angle Memory (some units)
When turning on your unit, the louver will
automatically resume its former angle.
• Refrigerant Leakage Detection (some
units)
The indoor unit will automatically display “EC” or
“EL0C”or flash LEDS (some units) when it detects
refrigerant leakage.
• Sleep Operation
The SLEEP function is used to decrease energy
use while you sleep (and don’t need the same
temperature settings to stay comfortable). This
function can only be activated via remote control.
And the Sleep function is not available in FAN or
DRY mode.
Press the SLEEP button when you are ready to
go to sleep. When in COOL mode, the unit will
increase the temperature by 1°C (2°F) after 1
hour, and will increase an additional 1°C (2°F)
after another hour. When in HEAT mode, the unit
will decrease the temperature by 1°C (2°F) after
1 hour, and will decrease an additional 1°C (2°F)
after another hour. The sleep feature will stop
after 8 hours and the system will keep running
with final situation.
Set
temperature
1hr
1hr
Keep
running
SLEEP Operation
Saving energy during sleep
Heat mode( -1 C/2 F) per hour
for the first two hours
Cool mode(+1 C/2 F) per hour
for the first two hours
Set
temperature
Keep running
Cool mode (+1 °C/2 °F) per hour for the
first two hours
Heat mode ( -1 °C/2 °F) per hour for the
first two hours
Saving energy during sleep
SLEEP Operation