Local air conditioner/User Manual
19 / EN
by refrigerant loss and a
refrigerant leak is possible.
• Discharge capacitors in a way
that won’t cause any spark.
The standard procedure to
short circuit the capacitor
terminals usually create
sparks.
• Reassemble sealed enclosures
accurately. If seals are worn,
replace them.
• Check safety equipment before
putting into service.
c) Repair
• Portable equipment shall
be repaired outside or in a
workshop specially equipped
for servicing units with
flammable refrigerants.
• Ensure sufficient ventilation at
the repair place.
• Be aware that malfunction of
the equipment may be caused
by refrigerant loss and a
refrigerant leak is possible.
• Discharge capacitors in a way
that won’t cause any spark.
• When brazing is required, the
following procedures shall be
carried out in the right order:
– Remove the refrigerant. If
the recovery is not required
by national regulations, drain
the refrigerant to the outside.
Take care that the drained
refrigerant will not cause any
danger. In doubt, one person
should guard the outlet. Take
special care that drained
refrigerant will not float back
into the building.
– Evacuate the refrigerant circuit.
– Purge the refrigerant circuit
with nitrogen for 5 min.
Evacuate again.
– Remove parts to be replaced
by cutting, not by flame.
– Purge the braze point with
nitrogen during the brazing
procedure.