Local air conditioner/User Manual
13 / EN
equipment is to be surveyed
to make sure that there are
no flammable hazards or
ignition risks. “No Smoking”
signs shall be displayed.
1.7 Ventilated area
Ensure that the area is
in the open or that it is
adequately ventilated before
breaking into the system or
conducting any hot work. A
degree of ventilation shall
continue during the period
that the work is carried
out. The ventilation should
safely disperse any released
refrigerant and preferably
expel it externally into the
atmosphere.
1.8 Checks to the refrigeration
equipment
Where electrical components
are being changed, they shall
be fit for the purpose and to
the correct specification. At
all times the manufacturer’s
maintenance and service
guidelines shall be followed.
If in doubt consult the
manufacturer’s technical
department for assistance.
The following checks shall
be applied to installations
using flammable refrigerants:
the charge size is in
accordance with the room
size within which the
refrigerant containing parts
are installed; the ventilation
machinery and outlets are
operating adequately and
are not obstructed; if an
indirect refrigerating circuit
is being used, the secondary
circuit shall be checked for
the presence of refrigerant;
marking to the equipment
continues to be visible and
legible. Markings and signs
that are illegible shall be
corrected; refrigeration pipe
or components are installed
in a position where they
are unlikely to be exposed
1 Safety awareness