Split type air conditioner / User Manual
2.2.6 No ignition sources
No person carrying out work in relation to a
refrigeration system which involves exposing
any pipe work shall use any sources of ignition
in such a manner that it may lead to the risk of
fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept
sufficiently far away from the site of installation,
repairing, removing and disposal, during which
refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the
area around the equipment is to be surveyed to
make sure that there are no flammable hazards
or ignition risks. “No Smoking” signs shall be
displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is
adequately ventilated before breaking into the
system or conducting any hot work. A degree of
ventilation shall continue during the period that
the work is carried out. The ventilation should
safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
2.2.8 Checks to the refrigeration
equipment
Where electrical components are being changed,
they shall be fit for the purpose and to the correct
specification. At all times the manufacturer’s
maintenance and service guidelines shall be
followed. If in doubt, consult the manufacturer’s
technical department for assistance.
The following checks shall be applied to
installations using flammable refrigerants:
-
the charge size is in accordance with the room
size within which the refrigerant containing
parts are installed;
-
the ventilation machinery and outlets are
operating adequately and are not obstructed;
-
if an indirect refrigerating circuit is being used,
the secondary circuit shall be checked for the
presence of refrigerant;
-
marking to the equipment continues to be
visible and legible. Markings and signs that are
illegible shall be corrected;
-
refrigeration pipe or components are installed
in a position where they are unlikely to be
exposed to any substance which may corrode
refrigerant containing components, unless
the components are constructed of materials
which are inherently resistant to being
corroded or are suitably protected against
being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components
shall include initial safety checks and component
inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall
be connected to the circuit until it is satisfactorily
dealt with. If the fault cannot be corrected
immediately but it is necessary to continue
operation, an adequate temporary solution shall
be used. This shall be reported to the owner of
the equipment so all parties are advised.
Initial safety checks shall include:
•
that capacitors are discharged: this shall be
done in a safe manner to avoid possibility of
sparking;
•
that no live electrical components and wiring
are exposed while charging, recovering or
purging the system;
•
that there is continuity of earth bonding.
2 Maintenance instruction